New energy relay high voltage DC relay-YEV50

New energy relay high voltage DC relay-YEV50

Short Description:

Main feature: Small size, light weight and arbitrary installation position; Use special epoxy resin sealing structure with ceramic characteristics to ensure that the arc does not leak, and the coil and contacts will not be oxidized and contaminated; Rated 400V, 50A contact switching capability; Maximum switching capacity of 125kW Product meets IEC61810-7; 2006 and fundamental 4048.4-2010 requirements Technical Parameters: Physical parameter Main contact contact form    1H Weight  ≤1...


Product Detail

Product Tags

Main feature:
Small size, light weight and arbitrary installation position;
Use special epoxy resin sealing structure with ceramic characteristics to ensure that the arc does not leak, and the coil and contacts will not be oxidized and contaminated;
Rated 400V, 50A contact switching capability;
Maximum switching capacity of 125kW
Product meets IEC61810-7; 2006 and fundamental 4048.4-2010 requirements
Technical Parameters:

Physical parameter
Main contact contact form   

1H

Weight 

≤190g

Contact parameter

 

Parameter

typical

Main contact contact form

    1H

Working voltage

12-900Vdc

Rated operating current
Working current (3min)

100 A 200 A 

50A@+450VDC
100A@+450VDC
100A@-450VDC
200A@+450VDC
1000A@+450VDC (breaking only)
600A@-450VDC
Maximum breaking current
    50000
    6000
    1000
    500
   10
   25
  1000A320VDC ≥1 times
Contact resistance              ≤1mΩ  (6VDC 2OA)
Dielectric withstand voltage
Disconnect between contacts
Between the contact and the coil
2200 Vrms @ sea level
(leakage current <1mA)
5600Vdc
2000Vdc
Mechanical life 

300000次

Insulation resistance
Between contacts
Between the contact and the coil
500Vdc
100MΩ (50MΩ after life)
100MΩ (50MΩ after life)
 Coil parameters (full temperature range)
Standard Voltage 12Vdc    24Vdc    48Vdc 
Maximum voltage 16Vdc    28Vdc    52Vdc
Pull-in voltage (20 ° C) 9Vdc     18Vdc    36Vdc
Release voltage (20 ° C) ≥1.2Vdc   ≥2.4Vdc   ≥3.6Vdc
Coil current (20 ° C) 461mA   255mA     122mA
Coil power (20 ° C) 5.5W      6.1W      5.9W
Pull-in voltage Max (+85 °C) 9.6Vdc    19.2Vdc     38.4Vdc
Coil resistance (20 ° C, ± 5%) Ω 26          96         392
Environmental performance  
Parameter 

typical

Impact 

11ms, 1/2 sine 20g

Vibration 

Sine wave, 55-2000HZ, 10g

工Operating temperature range

-40~+85 ℃

Action, release time
Parameter

 typical

Typical operating time

25 ms

Bouncing time

    5ms

Maximum release time

    7ms

Description:
Current level selection needs to be based on output wire specifications; and output terminals should be maintained the temperature is less than 175 °C.
Estimated product on/off life curve under resistive load:
The curve of the number of times of product on-off life expectancy under resistive load
YEV100
Remarks:

1. Suitable for resistive loads with a maximum inductance of 300uH.
2. The insulation strength between the terminals is reduced to 50 MΩ at the end of life.
3. This curve is an estimate of the inferred data and is only for reference when the customer uses it. It is recommended to confirm the experiment for different situations.
Order mark example:

YSEV50   A
Coil rated working voltage:   A=12V; B=24V; C=48V
Product serial number:YSEV50=12-900VDC, rated current 100A high voltage DC contactor

Note: The coil lead length can be customized.
Dimensions and installation dimensions:
CAONIDAYE
Precautions:

1. Use a washer to prevent the screws from loosening during installation.
The torque range of the tightening screw is as specified below. Exceeding the maximum torque can cause the product to rupture.
The force distance of the contact (M5 bolt): 3.4 -4.5N·m; the torque at the installation: 1.7-3.3 N·m.
2. The output end of this product is polar, so the connection should be operated according to the corresponding polarity.
3. Use products that have been dropped carefully.
4. Avoid installing the product in a location with strong magnetic fields (near the transformer or magnet) or near objects with thermal radiation.
5. Electrical life
This product is a mechanical contact switch. In its final failure mode, it may lose its proper shut-off function, so do not use it beyond its switching capacity and life parameters. Once the contactor loses its cutting ability, it may cause the surrounding parts to burn.
6. Internal gas diffusion life
This product is sealed with epoxy. The chamber is filled with inert gas. The diffusion life of the gas is determined by the temperature inside the contact chamber (ie ambient temperature + contact temperature rise). The working environment temperature should be -40 to +85 °C. .
7. When the resistive load is used, the rated value of the main contact in the rated value is applicable. If an inductive load (L load) is used and L/R>1ms, a surge current protection device should be connected in parallel with the inductive load.
8. Avoid miscellaneous materials and oil stains on the main lead-out; the external terminal should be in reliable contact with the main lead-out of the product, otherwise the lead-out will be severely heated.
 9. This product is recommended to use an altitude of 2500m or less. When the altitude exceeds 2500m, please contact the manufacturer.